Skip to content

Safety equipment inspection intervals

Pre-use, weekly, monthly, annual and multi-year checks for common safety equipment, on one page.

  • OSHA
  • ANSI
  • NFPA
  • ASME
  • ASTM

Checked against the sources on . General information, not legal advice.

Every kind of safety equipment runs on its own clock. Some need a 30-second check before each use, some a weekly test, and some carry multi-year deadlines that are easy to miss until an audit. This table puts the common intervals side by side so you can build one inspection calendar.

Inspection intervals by equipment

EquipmentMain standardsBefore use or dailyWeeklyMonthly6 months or yearlyMulti-year or event
Fire extinguishersOSHA 1910.157, NFPA 10Visual inspection, by a trained employeeYearly: maintenance by a certified technician6 years: internal exam (stored-pressure dry chemical); 5 or 12 years: hydrostatic test
Fall protection harnessesOSHA 1926.502, 1910.140, ANSI Z359.2Before each use or shift, by the wearerYearly: competent person (6 months in harsh conditions)Remove from service after any fall
Self-retracting lifelinesOSHA 1926.502, ANSI Z359.14Before each use, by the userYearly: competent personFactory service as the manufacturer says; remove from service after a fall
Eyewash stations and showersOSHA 1910.151(c), ANSI/ISEA Z358.1Activate plumbed unitsYearly: full inspection of flow, temperature and placement
Portable and fixed laddersOSHA 1910.23, 1926.1053, ANSI A14Before first use each shiftPeriodic: competent person in construction, commonly quarterly to yearlyInspect after any drop or impact
Slings and riggingOSHA 1910.184, ASME B30.9Daily before use, by a competent personSevere service: monthly to quarterlyYearly: documented periodic inspection, at leastProof test after any repair (chain slings)
ForkliftsOSHA 1910.178(q)(7)Before each shift; after each shift where used around the clockYearly: maintenance as the manufacturer says
Cranes and derricks, constructionOSHA 1926.1412Each shift, by a competent personDocumented, by a competent personYearly: comprehensive, by a qualified personAfter assembly, repair, modification, or 3+ months idle
Overhead and gantry cranesOSHA 1910.179, ASME B30.2Frequent: daily to monthlyFrequent: daily to monthlyPeriodic: every 1 to 12 monthsLoad test after an alteration or major repair
AEDs and first aid kitsManufacturer, FDA; ANSI/ISEA Z308.1 for kitsReadiness, seal and supply checkYearly: full contents and expiry checkAED pads and batteries by their expiry date, typically 2 to 5 years
Gas detectorsManufacturer, OSHA 1910.146 for confined spacesBump test before each day's use, as manufacturers recommendCalibration as the manufacturer says, often every 30 to 180 daysYearly: service if the manufacturer requires itSensor replacement at the end of its rated life
Respirators and SCBAOSHA 1910.134, NFPA 1852Before each use and during cleaningEmergency-use respirators and SCBAYearly: fit test (tight-fitting); SCBA flow test3 or 5 years: SCBA cylinder hydrostatic test, by cylinder type
Electrical insulating glovesOSHA 1910.137, ASTM F496Visual and air test before each day's useEvery 6 months: electrical retest once issuedRetest before issue if not tested within 12 months
Lockout/tagout proceduresOSHA 1910.147(c)(6)Yearly: periodic inspection of each energy control procedure

A calendar by rhythm

If you are building a calendar from scratch, group inspections by how often they happen, not by department:

  • Before use or daily, by workers and operators: harnesses and lifelines, ladders, slings, forklifts, crane shift checks, gas detector bump tests, glove air tests and respirators.
  • Weekly, by facilities technicians: eyewash and shower activation.
  • Monthly, by EHS or trained technicians: extinguisher inspections, construction crane monthly inspections, AED and first aid kit checks, emergency-use respirators and SCBA, and rigging in severe service.
  • Every 6 months, by a vendor or lab: electrical glove retests, and harness inspections for crews in harsh conditions.
  • Yearly, by a competent person, qualified person or certified vendor: extinguisher maintenance, harness and lifeline inspections, eyewash inspections, sling and crane inspections, fit tests and lockout/tagout procedure inspections.
  • Multi-year: extinguisher 6-year examinations and hydrostatic tests, SCBA cylinder tests, AED pads and batteries, and gas detector sensors.

Four things that override any schedule

An interval is the longest you may wait, not a promise the item is fine until then.

  1. An impact, a drop or a fall. A harness that arrested a fall, a ladder dropped from a scaffold, or an extinguisher knocked off its bracket is inspected now, even if it passed yesterday.
  2. Harsh conditions. Concrete dust, welding spatter, salt air, chemicals and heavy daily use call for shorter intervals than the usual yearly one.
  3. The manufacturer's instructions. If the manual asks for a 6-month inspection or a factory service, follow the stricter rule. OSHA expects equipment to be used and maintained as the manufacturer says.
  4. Fire marshals and state plans. Your authority having jurisdiction and state OSHA plans, such as Cal/OSHA, can set shorter intervals or require tags that federal OSHA does not.

GreenTagWorks

Every inspection clock in one place

Put each item on its own schedule, from weekly eyewash activations to 12-year hydrostatic tests. Due and overdue inspections show up on the inspector's phone and on your screen by site, and every inspection is signed and kept on the item's record. You pay for the equipment you inspect, not for each person who inspects it.

Official sources

This guide summarizes publicly available requirements for general information. It is not legal advice. Standards change and local codes, state plans and manufacturers can ask for more, so check the official text, the manufacturer's instructions and your authority having jurisdiction, or ask a qualified safety professional, before relying on it.

Put every inspection on a schedule

Load your equipment, set how often each item is inspected, and inspect from a phone. GreenTagWorks keeps the signed record.