Safety equipment inspection intervals
Pre-use, weekly, monthly, annual and multi-year checks for common safety equipment, on one page.
- OSHA
- ANSI
- NFPA
- ASME
- ASTM
Checked against the sources on . General information, not legal advice.
Every kind of safety equipment runs on its own clock. Some need a 30-second check before each use, some a weekly test, and some carry multi-year deadlines that are easy to miss until an audit. This table puts the common intervals side by side so you can build one inspection calendar.
Inspection intervals by equipment
| Equipment | Main standards | Before use or daily | Weekly | Monthly | 6 months or yearly | Multi-year or event |
|---|---|---|---|---|---|---|
| Fire extinguishers | OSHA 1910.157, NFPA 10 | Visual inspection, by a trained employee | Yearly: maintenance by a certified technician | 6 years: internal exam (stored-pressure dry chemical); 5 or 12 years: hydrostatic test | ||
| Fall protection harnesses | OSHA 1926.502, 1910.140, ANSI Z359.2 | Before each use or shift, by the wearer | Yearly: competent person (6 months in harsh conditions) | Remove from service after any fall | ||
| Self-retracting lifelines | OSHA 1926.502, ANSI Z359.14 | Before each use, by the user | Yearly: competent person | Factory service as the manufacturer says; remove from service after a fall | ||
| Eyewash stations and showers | OSHA 1910.151(c), ANSI/ISEA Z358.1 | Activate plumbed units | Yearly: full inspection of flow, temperature and placement | |||
| Portable and fixed ladders | OSHA 1910.23, 1926.1053, ANSI A14 | Before first use each shift | Periodic: competent person in construction, commonly quarterly to yearly | Inspect after any drop or impact | ||
| Slings and rigging | OSHA 1910.184, ASME B30.9 | Daily before use, by a competent person | Severe service: monthly to quarterly | Yearly: documented periodic inspection, at least | Proof test after any repair (chain slings) | |
| Forklifts | OSHA 1910.178(q)(7) | Before each shift; after each shift where used around the clock | Yearly: maintenance as the manufacturer says | |||
| Cranes and derricks, construction | OSHA 1926.1412 | Each shift, by a competent person | Documented, by a competent person | Yearly: comprehensive, by a qualified person | After assembly, repair, modification, or 3+ months idle | |
| Overhead and gantry cranes | OSHA 1910.179, ASME B30.2 | Frequent: daily to monthly | Frequent: daily to monthly | Periodic: every 1 to 12 months | Load test after an alteration or major repair | |
| AEDs and first aid kits | Manufacturer, FDA; ANSI/ISEA Z308.1 for kits | Readiness, seal and supply check | Yearly: full contents and expiry check | AED pads and batteries by their expiry date, typically 2 to 5 years | ||
| Gas detectors | Manufacturer, OSHA 1910.146 for confined spaces | Bump test before each day's use, as manufacturers recommend | Calibration as the manufacturer says, often every 30 to 180 days | Yearly: service if the manufacturer requires it | Sensor replacement at the end of its rated life | |
| Respirators and SCBA | OSHA 1910.134, NFPA 1852 | Before each use and during cleaning | Emergency-use respirators and SCBA | Yearly: fit test (tight-fitting); SCBA flow test | 3 or 5 years: SCBA cylinder hydrostatic test, by cylinder type | |
| Electrical insulating gloves | OSHA 1910.137, ASTM F496 | Visual and air test before each day's use | Every 6 months: electrical retest once issued | Retest before issue if not tested within 12 months | ||
| Lockout/tagout procedures | OSHA 1910.147(c)(6) | Yearly: periodic inspection of each energy control procedure |
A calendar by rhythm
If you are building a calendar from scratch, group inspections by how often they happen, not by department:
- Before use or daily, by workers and operators: harnesses and lifelines, ladders, slings, forklifts, crane shift checks, gas detector bump tests, glove air tests and respirators.
- Weekly, by facilities technicians: eyewash and shower activation.
- Monthly, by EHS or trained technicians: extinguisher inspections, construction crane monthly inspections, AED and first aid kit checks, emergency-use respirators and SCBA, and rigging in severe service.
- Every 6 months, by a vendor or lab: electrical glove retests, and harness inspections for crews in harsh conditions.
- Yearly, by a competent person, qualified person or certified vendor: extinguisher maintenance, harness and lifeline inspections, eyewash inspections, sling and crane inspections, fit tests and lockout/tagout procedure inspections.
- Multi-year: extinguisher 6-year examinations and hydrostatic tests, SCBA cylinder tests, AED pads and batteries, and gas detector sensors.
Four things that override any schedule
An interval is the longest you may wait, not a promise the item is fine until then.
- An impact, a drop or a fall. A harness that arrested a fall, a ladder dropped from a scaffold, or an extinguisher knocked off its bracket is inspected now, even if it passed yesterday.
- Harsh conditions. Concrete dust, welding spatter, salt air, chemicals and heavy daily use call for shorter intervals than the usual yearly one.
- The manufacturer's instructions. If the manual asks for a 6-month inspection or a factory service, follow the stricter rule. OSHA expects equipment to be used and maintained as the manufacturer says.
- Fire marshals and state plans. Your authority having jurisdiction and state OSHA plans, such as Cal/OSHA, can set shorter intervals or require tags that federal OSHA does not.
GreenTagWorks
Every inspection clock in one place
Put each item on its own schedule, from weekly eyewash activations to 12-year hydrostatic tests. Due and overdue inspections show up on the inspector's phone and on your screen by site, and every inspection is signed and kept on the item's record. You pay for the equipment you inspect, not for each person who inspects it.
Official sources
- OSHA 29 CFR 1910.157, Portable fire extinguishers
- OSHA 29 CFR 1926.502, Fall protection systems criteria and practices
- OSHA 29 CFR 1910.151, Medical services and first aid
- OSHA 29 CFR 1910.184, Slings
- OSHA 29 CFR 1910.178, Powered industrial trucks
- OSHA 29 CFR 1910.137, Electrical protective equipment
- OSHA 29 CFR 1910.134, Respiratory protection
- OSHA 29 CFR 1910.147, The control of hazardous energy
This guide summarizes publicly available requirements for general information. It is not legal advice. Standards change and local codes, state plans and manufacturers can ask for more, so check the official text, the manufacturer's instructions and your authority having jurisdiction, or ask a qualified safety professional, before relying on it.