Portable and fixed ladder inspection requirements
Pre-shift and periodic checks, tagging out a defective ladder, and the fixed ladder cage deadline.
- OSHA 1910.23
- OSHA 1926.1053
- ANSI A14
Checked against the sources on . General information, not legal advice.
Each shift
Pre-use check (general industry)
- Who
- A trained user
- Record
- Not required by OSHA
Periodically
Inspection (construction)
- Who
- A competent person; many programs do it quarterly
- Record
- Recommended, per ladder
Yearly
Fixed ladder and ladder safety system check
- Who
- Facilities or EHS, or a competent person
- Record
- Recommended
After a drop or impact
Inspect before it is used again
- Who
- A competent person (construction) or trained inspector
- Record
- Yes, with the result
On this page
Ladders are among the most often cited equipment in workplace safety, partly because they move between trucks, warehouses and jobsites every day without anyone tracking their condition. Your OSHA duties depend on whether the work is general industry (29 CFR 1910.23) or construction (29 CFR 1926.1053). The ANSI A14 standards set the design, duty ratings and care that manufacturers build into each ladder.
General industry vs. construction
Both rules aim to keep defective ladders out of use, but they set the inspection differently:
- General industry, 1910.23(b)(9): ladders are inspected before initial use in each work shift, and more often as needed, for visible defects that could cause injury. This covers portable and fixed ladders in warehouses, plants and commercial buildings.
- Construction, 1926.1053(b)(15): ladders are inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use, such as a fall or tip-over. OSHA does not define "periodic," so most construction programs pair a check before each use with a documented quarterly or semi-annual inspection.
The fixed ladder cage deadline: 1910.28(b)(9)
If you have fixed ladders that extend more than 24 feet above a lower level, keep this on the yearly checklist:
- Installed on or after November 19, 2018: must have a personal fall arrest system or a ladder safety system (a vertical cable or rail). A cage or well alone is not enough.
- Installed before November 19, 2018: cages and wells must be replaced with a personal fall arrest or ladder safety system by November 18, 2036.
- Repairs: when any section of such a ladder, cage or well is replaced before then, that section must get a personal fall arrest or ladder safety system.
Where ANSI A14 fits in
The ANSI A14 standards, from the American Ladder Institute, cover how ladders are built, rated, labeled and cared for:
- A14.1: portable wood ladders
- A14.2: portable metal ladders
- A14.3: fixed ladders
- A14.5: portable reinforced plastic (fiberglass) ladders
Two things they add to an inspection:
- Duty rating. Every portable ladder carries a duty rating label: Type IAA 375 lb, Type IA 300 lb, Type I 250 lb, Type II 225 lb, Type III 200 lb. Check the label is there, and that crews are not using light-duty Type II or III ladders for industrial work.
- Fiber bloom. Fiberglass ladders left in strong sunlight break down at the surface and show loose glass fibers on the rails. That weakens the rail and reduces its electrical insulation.
What to check
Portable ladders: step, extension, straight and platform
- Side rails: top to bottom, no cracks, splits, dents, bends, warping, fiber bloom or heat blisters.
- Rungs and steps: tight, level, not bent or cracked, no missing rivets, no oil, grease or wet paint.
- Feet: non-slip pads or swivel shoes are there, not worn smooth, and move freely.
- Spreaders and hinges (stepladders): lock firmly and are not bent, rusted or loose.
- Locks, pulley and rope (extension ladders): rung locks engage on both rails; the rope is not frayed or rotten; the pulley turns freely.
- Top cap and hardware: no cracked top cap, missing bolts or rivets, or loose end caps.
- Labels: the manufacturer's instructions and duty rating label are present and readable.
Fixed ladders: roof access, tanks, mezzanines and pits
- Mounts and anchors: every bracket, anchor bolt and weld is free of rust, loose fasteners, cracked concrete and separation from the structure.
- Rungs and rails: no heavy corrosion (look closely near roof hatches and outdoor bases), bent or loose rungs, or sharp burrs.
- Clearances: nothing new in the way. OSHA requires at least 7 inches behind the rungs (4.5 inches in elevator pits) and 30 inches clear on the climbing side.
- At the top: side rails extend at least 42 inches above the landing, and self-closing gates swing shut.
- Ladder safety systems: cables, rails, sleeves and anchors checked as the manufacturer says.
Remove from service if
- A side rail is cracked, split, bent, twisted or heat damaged.
- A rung, step or cleat is broken, bent, loose or missing.
- Safety feet are missing, broken or worn smooth.
- A spreader or rung lock is bent or does not work.
- The extension rope is frayed or rotten, or the pulley is broken.
- Rivets are missing, bolts are loose, or there is heavy corrosion.
- Fiberglass rails have deep gouges, delamination or heavy fiber bloom.
- A fixed ladder has loose anchors or a damaged safety cable.
Tagging out a defective ladder
A status in software does not stop the next person picking up the ladder. OSHA requires the ladder itself to show it is defective:
- General industry, 1910.23(b)(10): tag it "Dangerous: Do Not Use" or similar right away, and remove it from service until it is repaired or replaced.
- Construction, 1926.1053(b)(16): mark a defective portable ladder as defective or tag it "Do Not Use", and withdraw it from service until repaired.
- Construction, fixed ladders, 1926.1053(b)(17): withdraw it from service by tagging it "Do Not Use", marking it as defective, or blocking it, for example with plywood fixed across several rungs.
Repair or destroy?
Under 1926.1053(b)(18), a repair must bring the ladder back to its original design criteria before it is used again.
- Usually replaceable: parts the manufacturer supplies, such as feet, ropes, pulleys and replacement labels.
- Never repair in the field: do not weld aluminum rails, splice wood rails or tape cracked fiberglass. When the rails or rungs of a ladder fail, cut the rails before you scrap it so it cannot come back out of the dumpster.
Records
OSHA does not require a written log of every pre-shift check. After a fall, though, an inspection program with no records is very hard to defend.
Give every portable and fixed ladder its own ID, and record each periodic inspection and each check after an incident:
- Ladder ID, type, material, length and duty rating
- Where it lives: site, truck or crew
- Date and the inspector's full name
- Pass or fail, with photos of any damage
- Tag-out, repair, or the date it was destroyed
GreenTagWorks
Keep defective ladders off your jobsites
Every ladder gets its own record, wherever it travels: the van, the warehouse or the crew that has it. Inspectors scan its barcode, QR or NFC tag, run the checklist on a phone, and photograph a cracked rail or worn feet. A failed ladder goes out of service at once, so the whole team sees it is not to be used, and you still tag the ladder itself.
Official sources
- OSHA 29 CFR 1910.23, Ladders (general industry)
- OSHA 29 CFR 1910.28, Duty to have fall protection (fixed ladders)
- OSHA 29 CFR 1926.1053, Ladders (construction)
- ANSI blog: ANSI ASC A14.2, portable metal ladders
This guide summarizes publicly available requirements for general information. It is not legal advice. Standards change and local codes, state plans and manufacturers can ask for more, so check the official text, the manufacturer's instructions and your authority having jurisdiction, or ask a qualified safety professional, before relying on it.